Studi Analisa Efisiensi Konsumsi Energi Listrik pada Kapal Tug Boat Sei Deli DI PT. DOK dan Perkapalan Surabaya

  • Sri . Adiyansa Jurusan Teknik Elektro Fakultas Teknik UNESA, SUrabaya
  • Subuh Isnur Haryudo Jurusan Teknik Elektro Fakultas Teknik UNESA, SUrabaya

Abstract

Abstrak

Studi analisis ini mengkaji tentang konsumsi energi listrik, penghematan energi listrik dan perubahan harmonisa di kapal Tug Boat Sei Deli di PT. Dok dan Perkapalan Surabaya. Analisis data dilakukan dengan cara pengumpulan data,  dan perhitungan nilai kapasitor bank dan simulasi menggunakan program software ETAP (Electrical Transient Analysis Program). Hasil dari penelitian efisiensi konsumsi energi listrik, dapat diketahui bahwa setelah dilakukan perbaikan faktor daya sistem dengan menggunakan kapasitor bank berukuran 2 x 90 kVar di bus A dan B, maka power quality sistem kelistrikan mengalami peningkatan. Faktor daya pada bus utama sistem kelistrikan mengalami kenaikan hingga 90% yang pada awalnya sebesar 67,09%. Besarnya rugi-rugi daya sistem dapat diturunkan dikarenakan arus total pada sistem berkurang. Pada kondisi beban puncak yang awalnya bernilai 292,7 kVAR berkurang menjadi 157,3 kVAR. Selain perbaikan faktor daya pada penelitian ini dapat dilihat perubahan gelombang harmonisa yang awalnya memiliki banyak gelombang ganggu. Kapal tug boat sei deli melakukan penghematan sebesar Rp 2.648.497,00 setiap harinya, sehingga memerlukan waktu selama 27 hari untuk bisa melakukan penghematan secara maksimal setelah melakukan pengembalian biaya pembelian kapasitor bank yang dibutuhkan. Dan berkurangnya gelombang harmonisa yang terjadi setelah dikakukan perbaikan faktor daya dengan asumsi beban yang digunakan adalah tetap.

Kata Kunci: Efisiensi konsumsi energi listrik , faktor daya, penghematan energi listrik, harmonisa

 

Abstract

Study analyzes about the consumption of electrical energy, electrical energy savings and changes in harmonics on board Tug Boat Sei Deli at PT. DOK dan Perkapalan Surabaya. Data analysis is done by data collection, and calculation of capacitor bank and simulation using ETAP (Electrical Transient Analysis Program) software program. Result of research of efficiency of electric energy consumption, it can be seen that after improvement of power factor of system by using capacitor bank measuring 2 x 90 kVar at bus A and B, hence power quality of electrical system has increased. The power factor on the main bus of the electrical system increased up to 90% which initially amounted to 67.09%. The amount of system power losses can be lowered because the total current on the system is reduced. At peak load conditions that initially valued at 292.7 kVAR decreased to 157.3 kVAR. In addition to the improvement of power factor in this study can be seen harmonic wave changes that initially have many disturbing waves. Sei deli tug boat sees savings of Rp 2,648,497.00 per day, so it takes 27 days to be able to make the maximum savings after making the cost of purchasing the required bank capacitor. And the reduced harmonic wave that occurs after the power factor is fixed with the assumption that the load used is fixed.

Keywords: Efficiency of electric energy consumption, power factor, electricity energy saving, harmonicsi

Author Biographies

Sri . Adiyansa, Jurusan Teknik Elektro Fakultas Teknik UNESA, SUrabaya
Jurusan Teknik Elektro
Fakultas Teknik
UNESA, SUrabaya
Subuh Isnur Haryudo, Jurusan Teknik Elektro Fakultas Teknik UNESA, SUrabaya
Jurusan Teknik Elektro
Fakultas Teknik
UNESA, SUrabaya
Published
2018-09-01
Abstract Views: 153
PDF Downloads: 1355